All Guides โ€บ ISA Shunt Control โ€บ IsaInit
๐Ÿ“Š

ISA Shunt Control

How to Tune IsaInit on ZombieVerter VCU

ISA shunt init on startup.

Quick Reference

Param ID

75

Unit

enum

Range

0 โ€” 1

Default

0

Available Choices

0: Off (default) 1: On

๐Ÿ“– What Does It Do?

ISA shunt init on startup.

๐ŸŽฏ Recommended Values

Default value: 0

Valid range: 0 to 1

๐Ÿ’ก Tuning Tips

โš ๏ธ **CRITICAL INIT PROCEDURE:**

1. Set ISAmode=Init (On), click Save

2. Power cycle VCU AND shunt together (both must restart at same time)

3. Check 'udc' and 'idc' spot values โ€” should show real readings

4. IMMEDIATELY set ISAmode back to Normal (Off), click Save

5. Do NOT leave in Init mode โ€” it re-initializes every boot, resetting SOC

๐Ÿšจ **WIRING RULES:**
  • ISA shunt MUST have permanent 12V (not ignition-switched)
  • U1 terminal โ†’ inverter side of main contactor (load side), NOT battery side
  • 120ฮฉ termination resistor across shunt CAN H/L pins
  • Without correct wiring, precharge will fail (no DC bus measurement)