All Guides โ€บ Inverter Hardware โ€บ deadtime
๐Ÿ”Œ

Inverter Hardware

How to Tune deadtime on ZombieVerter VCU

IGBT dead time between high/low-side switching. CRITICAL safety param.

Quick Reference

Param ID

14

Unit

dig

Range

0 โ€” 255

Default

63

๐Ÿ“– What Does It Do?

IGBT dead time between high/low-side switching. CRITICAL safety param.

๐ŸŽฏ Recommended Values

Default value: 63

Valid range: 0 to 255

Tuning Strategy

Start with the default value and adjust in small increments. Monitor vehicle behavior after each change before making further adjustments.

๐Ÿ’ก Tuning Tips

โš ๏ธ **CRITICAL SAFETY!** Too low = both IGBTs conduct = instant destruction.

VALUES โ†’ APPROXIMATE DEAD TIME:

  • 28 โ†’ 800ns (minimum for small fast modules)
  • 50 โ†’ 1.2ยตs (Prius Gen2)
  • 63 โ†’ 1.5ยตs (DEFAULT โ€” safe for most)
  • 110 โ†’ 2.5ยตs (Infineon FS800)
  • 135 โ†’ 3.0ยตs (Ford Ranger)
  • 195 โ†’ 4.0ยตs (very conservative)
  • Always start conservative (100+) for unknown modules. Reduce only after testing at low power.

    Tune deadtime and All 80+ Parameters

    Answer a few questions about your specific build and get a complete, validated config file ready to load.

    Generate Your Complete Config โ†’