How to Tune udclim on ZombieVerter VCU

Maximum DC voltage during regen. Set to your pack's max charge voltage.

Quick Reference

Param ID

20

Unit

V

Range

0 โ€” 1000

Default

520

๐Ÿ“– What Does It Do?

Maximum DC voltage during regen. Set to your pack's max charge voltage.

๐ŸŽฏ Recommended Values

Default value: 520

Valid range: 0 to 1000

Inverter-Specific Recommendations

Leaf Gen1/2/3 403
GS450H 403
GS300H 403
Outlander 403
Rear Outlander 403
Prius Gen3 350

Tuning Strategy

Start with the default value and adjust in small increments. Monitor vehicle behavior after each change before making further adjustments.

๐Ÿ’ก Tuning Tips

96 cells ร— 4.2V = 403V. Set this 5-10V below your BMS overvoltage limit.

Prevents overvoltage during regen.